Thermolay is an underfloor electric heating system which is installed immediately under the finished
surface of tiles or stone slabs. It renders the floor surface warm to the touch and supplements other
heating in the same room.
Cable
Gives the best flexibility of layout and W/m
2
(heating power per unit area), but requires additional work
when laying. Three kit sizes cover areas from 1.2m
2
to 6.4m
2
.
Mat
Requires less work when laying than cable, but gives a fixed W/m
2
of 160. Six kit sizes cover sizes from
1.0m
2
to 5.0m
2
. Comes with self adhesive tape runs pre-attached for initially fixing mat to floor.
Flexi-Fast Mat This can be stretched lengthwise by 50% giving 133 to 200 W/m
2
. It requires the least work when laying
with the same flexibility of layout as the Mat. Six kit sizes cover areas from 1.6m
2
to 15.0m
2
.
At heat value of 200W/m
2
(Flexi-Fast unstretched) can be useful in getting the best level of underfloor heating in a conservatory but
it is not possible to rely on underfloor heating alone to heat a conservatory because of the large area of glazing, particularly the roof.
In other rooms (if the building meets the latest Building regulations) it is possible to heat the room with underfloor heating alone
if 200W/m
2
(Flexi-Fast unstretched) is used.
It is important that the correct size of mat/cable is used since the heating cable must not be cut. You will need to plan the layout carefully
(see section 4) prior to purchase and get the right size mat/cable for the installation. It is possible to use more than one mat/cable for an
installation by parallel connection but no cable in the system is allowed to cross over or under any other.
a. Electric Cable/Mat (one or more as required):
Cable Kits – 100 to 200 W/m
2
Part No
Length
Coverage
W
Ω
UFHC24
24m
1.2 to 2.4m
2
240W
220 Ω
UFHC32
32m
1.6 to 3.2m
2
320W
165 Ω
UFHC64
64m
3.2 to 6.4m
2
640W
83 Ω
Supplied with a reel of securing tape.
Mat Kits (Width 0.5m) – 160W/m
2
Part No
Length
Coverage
W
Ω
UFHM2 2m 1.0m
2
160W
330 Ω
UFHM3 3m 1.5m
2
240W
220 Ω
UFHM4 4m 2.0m
2
320W
165 Ω
UFHM6 6m 3.0m
2
480W
110 Ω
UFHM8 8m 4.0m
2
640W
83 Ω
UFHM10 10m 5.0m
2
,
800W
66 Ω
Securing tape built into webbing.
Flexi-Fast Mat Kits (Width 0.4m) – 133 to 200W/m
2
(Mat Width 0.4m, length can be stretched to 150% of figures
quoted) – 133 to 200W/m
2
Part No
Length
Coverage
W
Ω
FFM25
2.5m
1.0 to 1.5m
2
200W
264 Ω
FFM40
4.0m
1.6 to 2.0m
2
320W
165 Ω
FFM60
6.0m
2.5 to 3.7m
2
480W
110 Ω
FFM100
10.0m
4.0 to 5.0m
2
800W
66 Ω
FFM150
15.0m
6.0 to 9.0m
2
1200W
44 Ω
FFM250
25.0m
10.0 to 15.0m
2
2000W
26 Ω
Supplied with fixing pegs.
b. Controller
Installations without temperature control could give a floor
temperature of around 55°C which is not dangerously hot but is
wasteful of energy.
There are three controllers (temperature probe included) in the
Thermolay range, which, as well as regulating floor temperature by
means of an inclusive remote temperature probe, two of three will
define the time periods when the system is active. These are:-
TPT1 Electronic ON/OFF Thermostat
An electronic thermostat with ON/OFF control
and a 10º to 30ºC temperature range.
TPT44 24 Hour Digital Clock Thermostat
Programmable thermostat with a 24 hour clock
face which controls both underfloor and room
temperature.
TPT88 24 Hour/7 Day Multi-Programmable
Thermostat
Stylish 7 day programmable thermostat with
large display screen.
RAMSES 714 A Electronic Thermostat
An electronic thermostat with ON/OFF control
and a 10º to 30ºC probe temperature range.
All controllers come complete with a 4 metre
flying lead temperature probe.
c. RCD Protection
This is essential to give the highest level of
electrical safety protection. The 10 year
guarantee cover of mats and cables as
components is not effective unless the
installation is protected by an RCD.
This could be covering the total house supply but
a better solution would be to use the RCD10WPV
or the TPF10WL from the Thermolay range.
d. Screed
This is used to cover cable or mat and provide a
bedding to locate and restrain tiles/stone slabs.
The required screed is self levelling or latex and
it is possible to use standard flooring grade tile
adhesive. A different grade is usually
recommended for wood and concrete/screed
floors respectively. Suitable products are
manufactured by Ardex, Bal, Evostick and F.W.
Ball amongst others. Please consult your local tile stockist or DIY
store, who would also be able to recommend a suitable flexible
additive which is essential to be mixed with the adhesive and a
suitable primer for the floor surface.
e. Duct Tape
For the Mat and Flexi-Fast Mat systems you will need a reel of duct
tape (e.g. Duck) to fix the cold cable and probe with flying lead.
1. Introduction
2. What You Will Need
Thermolay Comes In Three Forms:
TPT88
RCD10WPV
RAMSES 714 A
TPT44
TPT1
Underfloor Heating Systems