1. Introduction

TRT products are a cost effective
comprehensive range of thermostats and
timers designed for internal use only.

The TRT038 is a three channel programmer,
and the TRT039 is a four channel
programmer. Each channel can be
programmed to have three on and off
operations per day. There is automatic
summer/winter time changeover.

The units are fitted with a factory
installed battery which gives up to
24 hours back up of time, date and
programmes in the event of a mains failure.

It is designed to be surface mounted
on the wall plate supplied.

The electrical supply must be isolated
before removing the programmer from
the wall plate.

2. Siting

The TRT038/9 should be located at a position
which eases wiring runs and gives good access

for programming.

It should be mounted approximately 1.5m

above floor level.

3. Installation

This product should be installed by a qualified
installer to current installation standards.
If in any doubt contact the Timeguard Helpline

020 8450 0515.

Contents

TRT038 or TRT039 programmer
TRT038/9 wall plate
TRT038/39 instruction leaflet
2 x wall plugs
2 x screws

14:23

Advance

Boost

Advance

Boost

Advance

Boost

Advance

Boost

HTG 1

0FF

0FF

HTG 2

ON until

WATER

ON until

Monday

25 Feb

HTG 3

Auto

22.30

Auto

22.30

14:23

Advance

Boost

Copy

Enter

Over

-ride

Advance

Boost

Advance

Boost

Menu

Reset

Advance

Boost

HTG 1

0FF

0FF

HTG 2

ON until

WATER

ON until

Monday

25 Feb

HTG 3

Auto

22.30

Auto

22.30

Channel status

displayed

(channel names

can be changed)

Buttons giving an

advance to next

programme change

Channel on

lights

Current time and

date displayed

Buttons giving

1 or 2 hours

timed on period

starting when

button is pressed

Fig. 1

TRT Central Heating Programmers

14:23

Advance

Boost

Advance

Boost

Advance

Boost

Advance

Boost

HTG 1

0FF

0FF

HTG 2

ON until

WATER

ON until

Monday

25 Feb

HTG 3

Auto

22.30

Auto

22.30

14:23

Advance

Boost

Copy

Enter

Over

-ride

Advance

Boost

Advance

Boost

Menu

Reset

Advance

Boost

HTG 1

0FF

0FF

HTG 2

ON until

WATER

ON until

Monday

25 Feb

HTG 3

Auto

22.30

Auto

22.30

Reset

button

Button to access or exit

the programming menu

Buttons for

changing times

and dates during

programming

Button for

entering times

and dates during

programming

Day copy

button

Buttons giving

permanently on,

permanently off,

timed (auto) or all

day alternatives

Fig. 1a

TRT Central Heating Programmers

L

Wiring for TRT038

Wiring for TRT039

L

L

L

N

N

N

N

ON

ON

230 VAC

230 VAC

ON

ON

ON

ON

ON

COM

COM

COM

COM

P1

P1

P2

P2

P3

P3

P4

P4

P5

P5

P6

Fig. 4

Wiring Diagrams

BM039

230V ~ 50Hz

T40 µ 3(1)A

Fixing hole

Retaining

tab

Wall plate retaining screws

(at bottom of TRT038 and TRT039)

Wire entry

L N P1 P2 P3 P4 P5 P6

Fig. 2

Fig. 3

Rear View of TRT039 (TRT038 similar)

Back Plate Removed

To reinstall the unit on the wall plate engage

the top of the TRT038/9 over the wall plate
retaining tabs (see Fig. 3), and push firmly
downwards and then inwards. There will be
some resistance from the terminals. Once in
place, secure with the retaining screws.

Restore mains to the unit after checking all
system wiring is complete.

The TRT038/9 is designed to be surface
mounted on the supplied wall plate.

Always isolate the mains supply before
removing the unit from its wall plate.

Incoming and outgoing wires should be 1.5mm sq.

Remove wall plate from unit, by undoing
retaining screws (see Fig. 2), and pivoting the
bottom of the wall plate outwards. The TRT038/9

can then be lifted off.

Thread the incoming wires through the hole in
the wall plate, and fix wall plate securely to the

wall, using screws (and wall plugs if necessary)
provided. The screws which secure the product

to the wall plate should point downwards.

Allow sufficient excess cable to wire up the unit,

but not too much to make it difficult to close the

unit onto the wall plate.

Connect the conductors to the relevant terminal,

according to the wiring diagrams on the wall
plates or in Fig. 4 below. Ensure that the curved
brass washers grip the conductors.

Programmers allow you to set ‘On’ and ‘Off’

time periods. Some models switch the central

heating and domestic hot water on and off at
the same time, while others allow the domestic
hot water and heating to come on and go off
at different times.
Set the ‘On’ and ‘Off’ time periods to suit your
own lifestyle. On some programmers you must

also set whether you want the heating and
hot water to run continuously, run under
the chosen ‘On’ and ‘Off’ heating periods,
or be permanently off.

The time on the programmer must be correct.

Some types have to be adjusted in spring and
autumn at the changes between Greenwich
Mean Time and British Summer Time.

You may be able to temporarily adjust the

heating programme, for example, ‘Override’,

‘Advance’ or ‘Boost’. These are explained in

the manufacturer’s instructions.

The heating will not work if the room thermostat

has switched the heating off. And, if you have a
hot-water cylinder, the water heating will not
work if the cylinder thermostat detects that the

hot water has reached the correct temperature.

®

What is a programmer?

...an explanation for householders

Note:

Check boiler

instructions

before connecting.

Note:

Check boiler

instructions

before connecting.

This manual is related to the following products: