beautypg.com

General rcd operation, If the rcd trips – Timeguard TFP10WL User Manual

Page 8

background image

8

7

General RCD Operation

Always test the RCD before use.

To test:

RESET – press the grey/blue button marked Reset (R), the status

indicator should show red.
TEST – press the red button marked Test (T), status indicator should

show black. This indicates that the RCD has been tripped and power

has been disconnected from the outlet.
RESET – press the grey/blue button marked Reset (R) again, the

status indicator should show red.
If all the above operations work satisfactorily, the RCD is safe for

use. If the procedure is not completed satisfactorily do not use the

RCD and seek professional advice.
In applications such as hand driers it may not be practical to expect

each user to test before use. In this case we suggest an appropriate

person applies the test routine twice a day.

To use:

After satisfactorily testing the RCD, any connected appliance may be

switched on, and used in the confidence that the user is protected

from electric shock by rapid disconnection.

If the RCD trips:

Turn the appliance switch off, press the Reset (R) button and note

that the status indicator turns red. Switch the appliance on and if the

RCD trips again, switch off the appliance and do not use it, as it may

be faulty. Seek professional advice.