5. Technical Specifi cations
Power Supply:
230V AC 50Hz
Lamp Type:
230V 60W (max) GLS or Halogen ES
Time ON Adjustment:
1 hour – 12 hours
Environmental Protection: IP44 (suitable for outdoor use)
6. Troubleshooting Guide
The level of ambient light in the area
may be too bright to allow operation
at the current DUSK setting. During
the hours of darkness, adjust the
DUSK control slowly clockwise
until the lamp illuminates. Refer to
previous section for more details.
The level of ambient light in the area
may be too dark for the current DUSK
setting. During daylight, adjust the
DUSK control slightly anti-clockwise
until the lamp load extinguishes.
The sensor will not
operate at night.
Unit activates during