Timeguard DS3HD User Manual
Page 9

9
• Remove front panel by unscrewing the four
fixing screws.
• If necessary, carefully remove the printed circuit
board (PCB) by undoing the four PCB mounting
screws.
• Remove knockouts at (preferably) the bottom of
the box.
• Use appropriate IP65 rated entry conduits to fit
M20 knockouts. Ensure tight fitting for IP compliance.
• Fix surface mount box rigidly to a secure surface
by using appropriate screws through the four.
fixing holes.
• Refit the PCB back onto the surface mount box
by progressively tightening each of the four PCB
mounting screws in turn. Do not over tighten
the screws
• Ensuring that the mains wires are adequate
for the required load cut the cable tails to the
appropriate lengths.
• Insert mains wiring through cable conduits.
• Connect the mains wires to the mains
connector as follows:
Figure 3 - Mains supply connector
Neutral
Neutral in
Earth
Live out
Live in
Designed in the U.K. 67-058-381
Timeguard Limited.
Victory Park, 400 Edgware Road,
London NW2 6ND
Sales Office: 020 8452 1112
or email [email protected]