Technical Data

641 0 100

641 0 300

642 0 100

642 0 300

644 0 100

644 0 300

Operating voltage / Frequency

Power consumption (typ.)

1,3 W

2,0 W

1,7 W

2,5 W

2,6 W

3,6 W

Standby

0,6 W

1,2 W

0,6 W

1,2 W

0,5 W

1,3 W

Switching output

DATA output

SELV - Safety Extra-Low Voltage

---

yes

---

yes

---

yes

Contact / Gap / Contact material

Switching capacity max. cos ϕ = 1

Switching capacity max. cos ϕ = 0,6

Switching capacity min.

Incandescent / Halogen lamp load 230 V~ (120 V~)

Fluorescent lamp load 230 V~ (120 V~)

- uncorrected, series corrected

- parallel correction
Compact fluorescent lamps 230 V~

(120 V~)

Permissible ambient temperature

Protection class

Protection rating

Time accuracy

Power reserve

Pollution degree

Power supply on the DATA bus

(maximum power on the DATA bus: 500 mA)

---

100 mA

---

100 mA

---

100 mA

II in accordance with EN 60730-1 subject to designated installation

IP 20 in accordance with EN 60529

±0.5 s / day at 20 °C

8 years (lithium call)

2

typ. –30 °C ... +45 °C,

temporary +55 °C

–30 °C ... +55 °C

2600 W (1300 W)

C1+C3: 2300 W (1150 W)

C2+C4: 2600 W (1300 W)

2300 VA (1150 VA)

1200 VA; 130 µF (600 VA; 65 µF)

37 x 7 W; 30 x 11 W; 26 x 15 W; 26 x 20 W; 23 x 23 W

(18 x 7 W; 15 x 11 W; 13 x 15 W; 13 x 20 W; 11 x 23 W)

110 – 240 V~, -15 %/+10 % , 50 - 60 Hz

phase independent

(not suitable for switching SELV)

two way switch / <3 mm (µ) / AgSnO

2

10 mA/230 V AC bzw. 100 mA/12 V AC/DC

10 A, 250 V~

16 A, 250 V~

C1+C3: 10A, 250 V~

C2+C4: 16 A, 250 V~

This manual is related to the following products: