Technical Data
641 0 100
641 0 300
642 0 100
642 0 300
644 0 100
644 0 300
Operating voltage / Frequency
Power consumption (typ.)
1,3 W
2,0 W
1,7 W
2,5 W
2,6 W
3,6 W
Standby
0,6 W
1,2 W
0,6 W
1,2 W
0,5 W
1,3 W
Switching output
DATA output
SELV - Safety Extra-Low Voltage
---
yes
---
yes
---
yes
Contact / Gap / Contact material
Switching capacity max. cos ϕ = 1
Switching capacity max. cos ϕ = 0,6
Switching capacity min.
Incandescent / Halogen lamp load 230 V~ (120 V~)
Fluorescent lamp load 230 V~ (120 V~)
- uncorrected, series corrected
- parallel correction
Compact fluorescent lamps 230 V~
(120 V~)
Permissible ambient temperature
Protection class
Protection rating
Time accuracy
Power reserve
Pollution degree
Power supply on the DATA bus
(maximum power on the DATA bus: 500 mA)
---
100 mA
---
100 mA
---
100 mA
II in accordance with EN 60730-1 subject to designated installation
IP 20 in accordance with EN 60529
±0.5 s / day at 20 °C
8 years (lithium call)
2
typ. –30 °C ... +45 °C,
temporary +55 °C
–30 °C ... +55 °C
2600 W (1300 W)
C1+C3: 2300 W (1150 W)
C2+C4: 2600 W (1300 W)
2300 VA (1150 VA)
1200 VA; 130 µF (600 VA; 65 µF)
37 x 7 W; 30 x 11 W; 26 x 15 W; 26 x 20 W; 23 x 23 W
(18 x 7 W; 15 x 11 W; 13 x 15 W; 13 x 20 W; 11 x 23 W)
110 – 240 V~, -15 %/+10 % , 50 - 60 Hz
phase independent
(not suitable for switching SELV)
two way switch / <3 mm (µ) / AgSnO
2
10 mA/230 V AC bzw. 100 mA/12 V AC/DC
10 A, 250 V~
16 A, 250 V~
C1+C3: 10A, 250 V~
C2+C4: 16 A, 250 V~