Technical data – Timeguard LUNA 109 User Manual
Page 8
Technical Data
LUNA 109
LUNA 110
Nominal voltage:
220–240 V, ~, +10 %/–15 %
220–240 V, ~, +10 %/–15 %
Frequency:
50–60 Hz
50–60 Hz
On/off switch delay:
1 min.
0–20 min.
Power consumption:
ca. 3 VA
ca. 3 VA
Contact material:
AgSnO
2
AgSnO
2
Contact:
floating
phase-independent
(zero-crossover switching)
Gap:
<3 mm (μ)
<3 mm (μ)
Switching capacity max.:
16 A, 250 V~, cos ϕ = 1
16 A, 250 V~, cos ϕ = 1
Switching capacity min.:
10 mA/230 V AC
10 mA/230 V AC
100 mA/12 V AC/DC
100 mA/12 V AC/DC
Switching capacity fluorescent lamps:
10 AX
16 AX
Incandescent lamp load:
2300 W
3600 W
Halogen lamp load:
2300 W
3600 W
Fluorescent lamp loads – capacitive ballast
uncorrected:
2300 VA
3600 VA
series corrected:
2300 VA
3600 VA
parallel corrected:
400 VA (42μF)
1200 VA (130μF)
dual circuit:
2300 VA
3600 VA
Fluorescent lamps – electronic ballast:
300 VA
1200 VA
Mercury and sodium vapour
lamps: series corrected:
400 VA (42μF)
1200 VA (130μF)
Compact fluorescent
lamps – electronic ballast:
9x 7W, 7x11 W,
34x7 W, 27x11 W, 24x15 W,
7x15 W, 7x20 W, 7x23 W
22x23 W
Permissible ambient temperature:
–30 °C ... +55 °C (device)
–30 °C ... +55 °C (device)
–40 °C ... +70 °C (sensor)
–40 °C ... +70 °C (sensor)
Protection class:
II (light sensors III) for designated installation
Protection rating:
IP 20, IP 55 (surface-mounted light sensor), IP 65 (built-in light sensor) in accordance
with EN 60529
8