Troubleshooting
Problem
Cause
Solution
Display does not light up
No Electricity
Check that the power supply cable is correctly
connected to both the chiller and outlet. Check that
the power switch is ON. Check that the fuse is intact.
Dirty Air Filter
Clean Air Filter as described on page 18.
Ambient Temperature
is too high
Lower the ambient temperature to below 95° F/35° C
Obstructed
Ventilation Grate
Remove the obstruction or create a ventilation hole.
Broken Fan
Contact service at [email protected]
UV lamp
Replace the UV lamp with an appropriate TECO UV
replacement, available at www.tecous.com
Water temperature
probe has been
damaged
Contact service at [email protected]
Compressor overload
probe is damaged
Check air filter, check that ventilation fans are running.
Contact service at [email protected]
Temperature displayed
is not correct
Water is losing or
gaining heat through
long and/or un-
insulated tubing
Reduce length of tubing, insulate the tubing.
Check for obstructions in tubing
Check that the pump is working
Water may not be circulating through chiller correctly
Chiller does not come on
until aquarium temperature
is several degrees higher
than set point
Temperature offset is
incorrect
Reset temp differential - see instructions below
Water flow through chiller
has slowed
Calcium Buildup
Disconnect chiller from aquarium. Run a 50% solution
of vinegar and water through chiller for 24 hours to
dissolve buildup. Thoroughly flush chiller with Ro/DI
before connecting to aquarium.
Press and hold “SET” for 10 seconds.
1
The display will show a value of 1 to 20 - this is the current set differential
Use the arrow Keys to change the set differential
2
The set differential reflects the number of degrees variance upward
from the set temperature you wish to allow. For example, if you have the
set temperature at 77° F, but do not want the chiller to turn on until it
reaches 80° F, set the differential value to 3. The default setting allows
a variance of 1.5° F from the set temperature before the chiller turns on.
This value is intended to protect the compressor from excessive wear, we
recommend a minimum of 1.5 set differential.
Changing UV Bulb
Turn off chiller and unplug the chiller, Remove the housing
1
(see directions on p.18)
Unscrew the ring nut for the UV sterilizer port.
2
Remove rubber stopper from the quartz sleeve
3
Unplug the old UV lamp from the 4-pin socket., remove and discard lamp.
4
Slide new UV lamp into quartz sleeve, plug into 4-pin socket, return rubber stopper into sleeve
5
Do not touch the glass of the UV bulb with your bare hands.
Tighten ring nut over quartz sleeve
6
Replace housing and screws
7
Open shut off valves, restart pump and check for leaks. Turn UV on by pressing UV button.
8
Hold down UV button for 10 seconds to reset AL2 code.
9
TR
30
TR
60
It is time to replace the UV Lamp
when the AL2 code flashes on the
control panel
Do not touch the glass of the UV bulb with your bare hands.
Oils on your hands will dramatically decrease the lifespan of the UV lamp. Use a clean
cloth to handle the lamp during installation.
WARNING: