Removing Housing
TR
5
TR
10
TR
15
TR
20
TR
30
TR
60
1
Turn off and unplug the chiller.
2
Remove screws from housing. Slide housing about 8" (20cm
back. Unplug green ground wire from housing. Slide the housing off. Keep the plastic washers that come
with the housing screws, these prevent chipping of the housing powder coat.
3
Slide Housing
completely off. Do not operate the chiller until housing is replaced.
1
Turn off and unplug the chiller.
2
Remove shut off valves by unscrewing ring nuts Remove
housing ring nuts and gaskets. You may need to use a wrench or pliers to loosen the ring nuts, we recommend
placing a cloth over the ring nut to prevent damage to the plastic
3
Pull out the air filter. Remove the
housing. First pull up on the case at the bottom, then pull up by gripping the back and the front control panel
recess. Do not operate the chiller until housing is replaced.
1
Turn off and unplug the chiller.
2
Remove shut off valves by
unscrewing ring nuts. Remove housing ring nuts and gaskets. You may need to
use a wrench or pliers to loosen the ring nuts,we recommend placing a cloth over
the ring nut to prevent damage to the plastic.
3
Pull out the air filter.
Unscrew and remove screws on the bottom. Use a phillips head screwdriver. You
may have to move the chiller to the edge of a table to do this.
4
Remove the housing. Housing will remain attached to chiller via electric cables. Grasp the
bottom of the chiller and the edge of the power socket, pull up and turn housing over and to the side. Do not
operate the chiller until housing is replaced.
Cleaning the Air Filter
It is essential to keep the air filter on the SeaChill clean. A clean air filter will ensure the unit is running at
maximum efficiency. All units have a sensor that will alert you if the air filter is being blocked. If the digital
display reads “AL1” this means the air filter is dirty or obstructed, and should be cleaned immediately.
For proper operation, clean the filter once per month.
1
Use a vacuum cleaner or rinse the filter under a sink until filter is clean.
2
Do not use soap or other
cleaning chemicals. Do not allow chiller to run for extended periods of time without an air filter.
Remove the filter from the bottom of the chiller.
TR
5
TR
10
TR
15
TR
20
Use a screwdriver to turn the plastic bolt 90˚
clockwise. (so the slot is vertical to the ground)
This unlocks the ventilation grate and allows
you to remove the air filter.
TR
30
TR