SPECIFICATIONS

Natural Gas Input

(Operating Range)

Min: 15,000 Btu/h

Max: 380,000 Btu/h

Propane Input

(Operating Range)

Min: 15,000 Btu/h

Max: 380,000 Btu/h

Gas Connection

1” NPT

Water Connections

1” NPT

Water Pressure

15 - 150 psi *

Natural Gas

Inlet Pressure

Min. 5.0” WC

Max. 10.5” WC

Propane

Inlet Pressure

Min. 8.0” WC

Max. 14.0” WC

Manifold Pressure**

Natural: 2.8” WC

Propane: 3.8” WC

Weight

102 lbs.

Dimensions

H25.3”×W24.8”×D11.8”

Ignition

Electric Ignition

Electric

Supply

120 VAC / 60 Hz

Consumption

Operation

178 W

(1.48A)

Standby

16 W

(0.13A)

Freeze-
Protection

271 W

(2.26A)

SPECIFICATIONS……………………….

INTRODUCTION…………………………

SAFETY GUIDELINES………………....

INSTALLATION…………………………..

General…………………………………

Included Accessories…….……………

Warning for Installations………………

Outdoor Installation……………………

Indoor Installation…………………......

Direct Intake Vent System…………….

Venting Instructions………………......

Gas Supply / Gas Pipe Sizing………..

Water Connections……………………

Pressure Relief Valve…………………

Electrical Connections……………......

Remote Controller Connection………

Pump Control Connections......……...

Pump Control Mode……………………

Easy-Link System………………………

Multi-Unit System………………………

Initial Operation………………………..

NORMAL OPERATION………………….

Normal Operation…………………......

Flow……………………………………..

Freeze Protection System…………...

Temperature Settings………………….

Maintenance and Service…………….

GENERAL TROUBLESHOOTING……..

OPERATING SAFETY………………...…

APPLICATIONS………………………......

Re-Circulation……………...................

Dual-Purpose Heating………………...

ADDITIONAL CLEARANCES……………

OPTIONAL ITEMS………...……………..

COMPONENTS DIAGRAM…………….

PARTS LIST………………………………

OUTPUT TEMPERATURE CHART……

LIMITED WARRANTY……………….......

2

3

5

6

7

7

8

9

10

11

12

16

19

19

20

21

22

23

24

27

29

30

30

32

32

33

34

35

38

40

40

41

42

43

44

48

51

51

The manufacturer reserves the right to discontinue, or change at any time,
specifications or designs without notice and without incurring obligations.

*40 psi or above is recommended for maximum flow.
**The Manifold Pressure is the factory setting and

generally should not need adjustment.