Chapter 3: Installation
19 of 41
NOTE: The distance set by the manufacturer for normal application is 0.006"
to 0.008" (0.15 mm to 0.20 mm). If the gap between the bed knives and the
rotor knives is greater than this range, an adjustment must be made. (See
“Inspection and Adjustment of Knives”.)
Once you have checked the knife gap, close the hopper and secure it with the
appropriate swing bolt. Reinsert the bin and close the front panel.