PEP Filters TOWER CLEAN PACKAGE User Manual
Page 3

System Installation and Startup
Technical Data
Maximum Pressure
10 bar
140 psi
Minimum Pressure
2.8 bar
38 psi
Backwash Flow Rate per unit 8 m
3
/hr 35
gpm
Maximum Temperature
70
°C 158°F
pH 4-11
4-11
2” Spin Klin Battery
Installation
A. Make sure that the inlet and outlet orientation is correct (shown by arrows on filter).
B. Prior to start-up check for any transport damage to the unit (system operates under pressure!).
C. Connect backwash drainage line.
D. Cover clamps need to be properly closed.
Start-up Operation
Start the backwash cycle, making sure that all system components function correctly.
Filter Load-up during Start-up
Close the downstream (flow control) valve (if available).
Flush few cycles until clean.
Slowly reopen the downstream valve.
If the pressure difference remains high, check and see if the flow rate is too high.
An excessive flow rate through the filter causes excessive pressure loss.