Identifying Malfunctions in the 2” Spin Klin system
Continuous or Non-stop Backwashing
Continuous backwash
Non stop backwash cycle
Disconnect the control
pipes from the valves
Check inlet / outlet pressure
Check pressure differential gauge and replace if needed
Check controller described above
Contact your local distributor
Command transfer
No command
transfer
Disconnect the drain manifold
Check controller
Locate the nonfunctioning valve
Remove any obstruction
Repair the valve if needed
No command transfer
Command transfer
Replace control
panel
Check the solenoid
No command transfer
Command transfer
Replace the
solenoid if needed
Contact your local distributor