Problem

Gas leaking from
LP Gas Cylinder

Gas leaking between
LP Gas Cylinder and regula-
tor connection

Grease fire or excessive
flames above cooking surface

Flashback (Fire in or around
Venturi tubes)

Possible Cause

Mechanical failure due to rust
or mishandling

Improper installation, con-
nection not tight, failure of
seal on LP Gas Cylinder

Too much grease build-up in
Burner section

Clogged or blocked Venturi
tube

Solution

Replace LP Gas Cylinder.

Remove LP Gas Cylinder. Re-install correctly and
tighten. Replace Cylinder if damaged. See “Leak Test”
and “Connecting Regulator to LP Gas Cylinder”
sections.

Turn off Regulator Knob and remove LP Gas Cylinder.
Once fire is out and grill has cooled off, clean residual
food particles and excess grease from inside firebox
area, grease cup, and other surfaces.

If you can safely reach the Regulator Knob, turn it to the
“OFF” position, then remove the LP Gas Cylinder. Once
grill has cooled, clean Burner and Venturi tubes. See
“How to Clean Burners” section.