Ouellet ORC User Manual
Page 2
Double-pole
Thermostat
(option)
Single-pole
Thermostat
(option)
L1
L2/N
Element
Figure 5
OPTIONS WIRING DIAGRAM
WALL
CEILING
TOP VIEW
REAR VIEW
34 in. to 113 in.
(864 mm to 2870 mm)
1 1/2 in.
(39 mm)
4 1/4 in.
(107 mm)
1 7/8 in.
(47 mm)
3 1/8 in.
(79 mm)
1 in. (25 mm) minimum between
bottom of heater and any fabric
6 ft. (1829 mm) minimum
clearance to fl oor
6 5/8 in. (168 mm) min. (dry wall ceiling)
7 1/8 in. (180 mm) min. (lay in or vinyl
ceiling or plastic molding)
4 in. (102 mm) min. (dry wall ceiling)
4 1/2 in. (114 mm) min. (lay in or vinyl ceiling or
plastic molding)
MOUNTING RESTRICTIONS
Spare Wire (not used)
Spare Wire
Spare Wire
Double-pole
Thermostat
(option)
Single-pole
Thermostat
(option)
Single-pole
Thermostat
(option)
Double-pole
Thermostat
(option)
L1
L2/N
L1
L2/N
Spare Wire
(not used)
Spare Wire
(not used)
Element
Element
Element
Element
Element
TWO OR MORE UNITS - SUPPLY AT END
TWO UNITS WIRING - SUPPLY IN MIDDLE
Figure 4
IMPORTANT : Total amperage should not be over 16 amperes