beautypg.com

W.e. anderson div., dwyer instruments, inc – Dwyer SAV-ST User Manual

Page 2

background image

Normally Closed

Normally Open

Valve

Size

1/2
3/4

1

1-1/4
1-1/2
1-1/2

2
2

Actuator

Diameter

2.76˝
2.76˝
3.32˝
3.32˝
4.58˝
4.58˝
4.58˝
5.54˝

Max. Line

Pressure

230
230
230
230
230
143
232
232

Max. Steam

Pressure

150
150
150
150
150
150
150
150

Flow

Direction

Overseat
Overseat
Overseat
Overseat
Overseat
Overseat
Overseat
Overseat

Min. Pilot

Pressure

60
60
60
60
60
60
60
60

Max. Pilot

Pressure

143
143
143

114
114
114
114
114

Max. Line

Pressure

230
230
290
230
230
230
160
220

Max. Steam

Pressure

150
150
150
150
150
150
150
150

Flow

Direction

Overseat
Overseat
Overseat
Overseat
Overseat
Overseat
Overseat
Overseat

Min. Pilot

Pressure

60
60
60
60
60
60
60
60

Max. Pilot

Pressure

143
143
143

114
114
114
114
114

Stainless Steel

Bronze

LINE AND PILOT PRESSURE CHARTS (psi)

INSTALLATION
1. Prior to Installation, be sure system is not under pressure and all
scale and debris is free from piping system.
2. The valve can be installed in any position, with the direction of flow
as indicated on the inlet/outlet ports by the connection numbers 1 and
2.
3. The actuator can be rotated 360 degrees in the direction indicated
on the product label to facilitate easy pilot mounting connection.
4. Apply thread tape or sealant to pipe threads only.
5. Use hex flats on valve to secure the valve and pipe. Never tighten
the valve by using the actuator to turn.
6. Pipework should be supported to prevent any stress on valve body.

OPERATION
1. Flow direction is from ports 2 to 1 for normally closed valves, For
liquids, flow should be under the seat to prevent waterhammer.
2. Pilot pressure is from 22-150 psi, dependent on process pressure.
Review pilot/media pressure relationship charts before initial system
operation.
3. Optional Series PV Solenoid Pilot Valves can be installed for
operation with 120 VAC power supply (other voltages available).

MAINTENANCE
The Series SAV requires no maintenance. Care should be taken to
make sure that the ratings of the valve are not exceeded with respect
to maximum pressures and temperatures, and that the media is
compatible with all materials.

SPARE PARTS
The Series SAV valve is completely safe to disassemble in the field. A
seal kit is available for all valves and actuator sizes compromising:
piston lip seal, actuator steam O-ring, plug soft seal (PTFE), body seal
and O-ring. Specify valve size and type when requesting a seal kit.

©Copyright 2014 Dwyer Instruments, Inc.

Printed in U.S.A. 3/14

FR# RV-443112-00 Rev. 4

W.E. ANDERSON DIV., DWYER INSTRUMENTS, INC.

P.O. BOX 358 • MICHIGAN CITY, INDIANA 46360 U.S.A.

Phone: 219/879-8000

www.dwyer-inst.com

Fax: 219/872-9057

e-mail: [email protected]

WARRANTY
The Series SAV is warranted from defects in materials or workmanship
for (1) year from the date of purchase. If required, contact our customer
service department for a Return Goods Authorization and send to:

Attn: Repair Department
Dwyer Instruments, Inc.
102 Indiana Highway 212
Michigan City, IN 46361

NOTES:

Valve

Size

1/2
3/4

1

1-1/4
1-1/2

2

Actuator

Diameter

2.76˝
2.76˝
3.32˝
3.32˝
4.58˝
5.54˝

Max. Line

Pressure

230
230
230
230
230
230

Max. Steam

Pressure

150
150
150
150
150
150

Flow

Direction

Underseat
Underseat
Underseat
Underseat
Underseat
Underseat

Min. Pilot

Pressure

60
60
60
60
60
60

Max. Pilot

Pressure

143
143
143

114
114
114

Max. Line

Pressure

230
290
290
230
230
220

Max. Steam

Pressure

150
150
150
150
150
150

Flow

Direction

Underseat
Underseat
Underseat
Underseat
Underseat
Underseat

Min. Pilot

Pressure

60
60
60
60
60
60

Max. Pilot

Pressure

143
143
143

114
114
114

Stainless Steel

Bronze

This manual is related to the following products: