Alicat MC Series Mass Flow Controller User Manual
Page 43
43
Opti on: Totalizing Mode - Controllers
Controllers can be purchased with the Totalizing Mode opti on. This opti on adds
an additi onal mode screen that displays the total fl ow (normally in the units of
the main fl ow screen) that has passed through the device since the last ti me the
totalizer was cleared. The Totalizing Mode screen is accessed by pushing the
TOTAL butt on on the MAIN display.
TOTAL/TIMER: Pushing the TOTAL/TIMER butt on
will cycle the large numbers on the display
between total mass and ti me elapsed.
Rollover – The customer can also specify at the
ti me of order what the totalizer is to do when
the maximum count is reached. The following
opti ons may be specifi ed:
No Rollover – When the counter reaches the
maximum count it stops counti ng unti l the
counter is cleared.
Rollover – When the counter reaches the
maximum count it automati cally rolls over to
zero and conti nues counti ng unti l the counter is cleared.
Rollover with Noti fi cati on – When the counter reaches the maximum count
it automati cally rolls over to zero, displays an overfl ow error, and conti nues
counti ng unti l the counter is cleared.
TOTAL MASS: The counter can have as many as seven digits. At the ti me of order,
the customer must specify the range. This directly aff ects the maximum count. For
instance, if a range of 1/100ths of a liter is specifi ed on a meter which is totalizing in
liters, the maximum count would be 99999.99 liters. If the same unit were specifi ed
with a 1 liter range, the maximum count would be 9999999 liters.
ELAPSED TIME: The small numbers below the mass total show the elapsed ti me
since the last reset in hours, minutes and seconds. The maximum measurable
elapsed ti me is 9999 hours 59 minutes 59 seconds. The hours count resets when
RESET is pushed, an RS-232 or RS-485 clear is executed or on loss of power. Press
ELAPSED TIME to show this as the primary display.
SETPT: Pushing SETPT will allow you to change the controller's set-point.
RESET – The counter can be reset to zero at any ti me by pushing the RESET
butt on. To clear the counter via RS-232 or RS-485, establish serial communicati on
with the meter or controller as described in the RS-232 or RS-485 secti on of the
manual. To reset the counter, enter the following commands:
In Polling (addressable) Mode: Address$$T
SETPT
+123.4
MENU
SCCM
+123.4
TOTAL/
TIMER
BATCH
RESET
0000:09:59 SCC
00123.45
00123.45 Batch Done