beautypg.com

Alicat Local SetPoint Module User Manual

Page 3

background image

1


INTRODUCTION:
The Local Set Point Module (LSPM) is designed to provide a simple
method to adjust and monitor the set point to your flow controller. It utilizes a convenient
one turn twist knob, a versatile LED display, and a set point tracking alarm LED in a simple
remote mountable package.

The LSPM reads the actual output signal, and can display the output parameter as well as the
set point.

Flow Controller connected to the LSPM using the Top Connector Socket

(this connection may also be made using the LSPM’s Bottom Connector Socket)



CONNECTIONS:
The LSPM requires a double ended DC-62 8 Pin Mini-DIN cable
connected between either the top or the bottom connector socket of the LSPM and the
connector socket on top of the controller. The two connector sockets on the LSPM are “pass
through” connected so that the unused socket can be connected to a DC-61 single ended
cable for connection of output signals and/or power. Appropriate power can be connected to
either the LSPM or the controller, whichever is more convenient.

DC-62 Double Ended
8Pin Mini-DIN Cable