CONDENSERS
C11 - 45 / CS50 - 105
Condensers
11
Technical Manual: 6469597 V1.3.0 02_2013
Performance Data
CAPACITY DATA
Standard Condenser Fan
Mean Condensing
Temperature °C
Ambient
25°C
30°C
35°C
40°C
45°C
48°C
Output kW
Output kW
Output kW
Output kW
Output kW
Output kW
C11HI
35
6.90
3.24
-
-
-
-
40
10.81
6.94
3.26
-
-
-
45
15.05
10.93
6.97
3.27
-
-
50
19.31
15.11
10.98
6.99
3.28
-
55
23.66
19.41
15.18
11.02
7.02
4.78
C15HI
35
10.27
4.76
-
-
-
-
40
16.21
10.37
4.80
-
-
-
45
22.28
16.36
10.45
4.83
-
-
50
28.49
22.51
16.49
10.51
4.85
-
55
34.95
28.81
22.73
16.61
10.57
7.14
C20HI
35
12.52
5.79
-
-
-
-
40
19.63
12.70
5.86
-
-
-
45
26.76
19.93
12.84
5.91
-
-
50
34.70
27.23
20.18
12.96
5.95
-
55
42.79
35.22
27.65
20.42
13.07
8.82
C25HI
35
15.98
7.41
-
-
-
-
40
25.35
16.06
7.44
-
-
-
45
35.17
25.47
16.13
7.47
-
-
50
45.22
35.31
25.57
16.18
7.49
-
55
55.50
45.47
35.47
25.66
16.22
10.99
C35HI
35
19.01
8.84
-
-
-
-
40
29.39
19.02
8.84
-
-
-
45
40.15
29.54
19.21
8.84
-
-
50
50.81
40.15
29.66
19.28
8.84
-
55
61.77
51.08
40.53
29.93
19.34
13.04
C45HI
35
28.88
13.47
-
-
-
-
40
45.10
29.22
13.60
-
-
-
45
61.55
45.64
29.47
13.70
-
-
50
78.93
62.34
46.09
29.69
13.79
-
55
96.91
79.84
63.05
46.51
29.89
20.28
CS50
35
31.70
13.61
-
-
-
-
40
50.53
32.16
14.13
-
-
-
45
69.27
51.15
32.79
14.76
-
-
50
88.16
70.02
51.84
33.48
15.38
-
55
107.28
89.08
70.99
52.68
34.29
23.00
CS65
35
44.30
20.92
-
-
-
-
40
68.27
44.76
21.43
-
-
-
45
91.99
68.71
45.27
21.88
-
-
50
115.85
92.51
69.26
45.90
22.51
-
55
140.04
116.52
93.21
69.98
46.67
32.35
CS80
35
51.98
22.90
-
-
-
-
40
82.36
52.84
23.88
-
-
-
45
112.52
83.36
53.79
24.84
-
-
50
142.90
113.75
84.50
54.89
25.81
-
55
173.65
144.39
115.16
85.84
56.19
37.96
CS105
35
71.53
34.06
-
-
-
-
40
109.82
72.21
34.83
-
-
-
45
147.74
110.49
73.00
35.50
-
-
50
185.90
148.51
111.32
73.95
36.48
-
55
224.58
186.90
149.56
112.42
75.14
52.26
(1)
Output kW refers to the condenser heat of rejection.
OPERATING LIMITS
Standard On/Off Head Pressure Control
Minimum Ambient Air DB °C
-0°C
Maximum Ambient Air DB °C
+48
Optional Variable Speed Head Pressure Control
Minimum Ambient Air DB °C
-20°C
Maximum Ambient Air DB °C
+48