Service

1 Complete servicing and repair of Techne products is available

at Techne see the contact information on pages 3 or 4.

2 A Service Manual is available and servicing may be undertaken by

any competent refrigeration engineer.

The following table gives a guide as to the gas charge for each
of the units:

Unit

Refrigerant §

Charge *

RB-5A

R134a

85 gm

RB-12A

R404a

250 gm

RB-22A

R404a

250 gm

* There have been several improvements in design which

have varied the charge. To increase the cool-down rate
increase the charge slightly; to reach a lower temperature
reduce the charge slightly. Adjust the charge during testing.

§ Early units were charged with R12 or R502 please consult

Techne for advice on repair of older units. Units charged with
R404a or R134a have GN after the Serial Number,
eg 12345-13gn.