19

5.3 Environmental Specifications

a. High Temperature

:

Design to MIL-STD-810C, method 501.1 procedure II

Operating temperature:

+70 °C (+160 °F)

Optional operating temperature:

+85 °C (+185 °F)

Storage temperature:

+85 °C (+185 °F)

b. Low Temperature:

Design to MIL-STD-810C, method 502.1, procedure I

Operating temperature: -40 °C (-40 °F)
Storage temperature:

-55 °C (-65 °F)


c. Humidity:

Designed to meet MIL-STD-810C, method 507.1, procedure IV
Relative humidity of up to 95% for the operational temperature range.

d. Salt and Fog:

Designed to meet MIL-STD-810C, method 509.1 procedure I.
Exposure to a 5% salt solution for 48 hours


e. Water and Dust:

IP66 & IP67 per EN 60529
NEMA 250 Type 6P


f. Shock and Vibration:

Vibration: Designed to meet MIL-STD-810C method 514.2, procedure 1.
Mechanical Shock: Designed to meet MIL-STD-810C method 516.1,
procedure 1.


g. Electromagnetic Compatibility (EMC):

The detector is design and approved according to the following EMC
requirements:

Electrostatic Discharge (ESD):

IEC801-2: 1984.

Conducted emission:

EN55022, Class A.

Radiated emission:

EN55022, Class A.

Radiated immunity:

IEC801-3: 1984.

EFT/B: IEC801-4:

1988.