The IP80-Series are impeller (or “paddlewheel”) insertion
metersdesignedforusewithawidevarietyofliquidsinpipe
sizes1/2"to8".Sensorsareavailableinbrass,316stain-
less steel, PVC, and polypropylene. Bodies are machined
fromasolidrodformaximumprecision.High-qualityjewel
bearingsandnickel-boundtungstencarbideshaftsareused
forextremelowfrictionandlonglife.Low-flowperformance
isgood,althoughotherSeametricsflowmetersarerecom-
mendedwhereextremelylowflowsarebeingmeasured.
Therotationoftherotorisdetectedbyanon-dragHall-ef-
fectsensor.Outputisacurrent-sinkingpulse(squarewave),
whichcanbesentlongdistances(upto2,000feet)without
atransmitter.ThissignalcanbeconnecteddirectlytoPLC's,
counters,andcomputercards,aswellasavarietyofSeam-
etricscontrolsanddisplays.
SeametricsIPmetersareidealforchemicalproportioning
applications.Ifnodisplayisrequired,asimpledividersuch
asthePD10providesadjustablepumppacing.Forrateand
totaldisplay,theFT415(batterypowered)orFT420(loop
powered)flowindicatorcanbemounteddirectlyontheIP80-
Seriesmeter,orremotelyonawallorpanel.TheAO55blind
analog transmitter can be used to convert to a 4-20 mA
output.IPmetersarealsocompatiblewiththeDL76data
loggerandFT520batchprocessor.
TheIP80-Seriesrequirespecialfittingsthatensurecorrect
depthplacementinthepipe.Fittingscomeinavarietyof
materialsforcompatibilitywithspecificapplications.Teefit-
tingsareindividuallywet-calibratedatthefactoryandmarked
withtheK-factor(pulsespergallon).Saddlefittingsmustbe
field-installedonthepipeanddonotcomewet-calibrated.
K-factorsforsaddlesarebasedonfactory-testing.
caution:U-clip
mustbeinstalled
beforeuse.
FEatuRES
Rotor
O-Ring
RetainingSlot(forU-Clip)
Foreasyinstallationatcorrectdepthsetting
LowerHousing(optional)
Cable-SealStrainRelief
HousingScrew
(connectgroundtoone)
CoverorOptionalModule
JewelBearingsforsuperiorlow-flowperformance
Page 3
tabLE OF cONtENtS
SPEcIFIcatIONS*
Brass,316StainlessSteel,PVC,orPolypro
PVDF
Nickel-bondedtungstencarbide(Ceramicoptional)
Rubyjewel
EPDM(Vitonoptional)
GMR(GiantMagnetoresistive)Sensor
brass
316 SS
PVc or Polypro
(SeePressurevs.Temp.Chart)
200PSI(14bar)
250PSI(17bar)
175PSI(12bar)@75˚F
200˚F(93˚C)
200˚F(93˚C)
130˚F(55˚C)
0.3-30ft./sec.
+/-1.5%offullscale
Halleffectcurrentsinkingpulse
6-24Vdc,2mA
20mA
#22AWG,3Cond,18foot(maximum2000’run)
Mark(StainlessSteel,BrassandStandardPowerOnly)
Materials Sensor body
Rotor
Shaft
bearings
O-Ring
Rotor Pickup
Maximum Pressure
Maximum temperature
Flow Range
accuracy
Signal
Power
Maximum current
cable
Regulatory
*Specifications subject to change • Please consult our website for current data (www.seametrics.com).
ARCHIVED
(Includes Dates Before 1/1/201
1)