beautypg.com

Archived – Seametrics IP80-Series User Manual

Page 11

background image

Problem

Probable cause

try...

No­­­­signal
after­­­­installation

Inaccurate
metering

Consult­­­­Flow­­­­Range­­­­Chart
Reduce­­­­pipe­­­­size­­­­or­­­­use­­­­different
sensor

Check­­­­connections­­­­at­­­­control;
Red­­­­(+),­­­­Black­­­­(-),­­­­White­­­­(signal)

Use­­­­6-24­­­­Vdc­­­­power­­­­supply
Add­­­­pull­­­­up­­­­resistor,­­­­if­­­­using­­­­current-
sourcing­­­­device

Remove­­­­flow­­­­sensor­­­­from­­­­fitting­­­­and­­­­check
for­­­­free­­­­spinning;­­­­replace­­­­rotor

See­­­­signal­­­­troubleshooting;­­­­replace
magnetic­­­­sensor

Move­­­­meter­­­­away­­­­from­­­­flow­­­­disturbance,­­­­or
field-calibrate

Check­­­­fitting­­­­for­­­­K-Factor,­­­­check­­­­indicator­­­­to
see­­­­if­­­­it­­­­is­­­­entered­­­­properly­­­­("Set­­­­K"­­­­on
FT420,­­­­FT415,­­­­FT520)

Remove­­­­flow­­­­sensor­­­­from­­­­pipe.­­­­If­­­­indicator
is­­­­FT415,­­­­FT420,­­­­FT520,­­­­set­­­­K­­­­to­­­­1.00,
turn­­­­rotor­­­­slowly­­­­by­­­­hand,­­­­indicator­­­­should
count­­­­each­­­­blade;­­­­replace­­­­sensor

If­­­­using­­­­FT415­­­­or­­­­FT420,­­­­check­­­­left­­­­side­­­­of
display­­­­(sec,­­­­min,­­­­hr,­­­­day);­­­­change­­­­to
desired­­­­unit

Insufficient­­­­flow

Bad­­­­connections­­­­to­­­­control­­­­electronics

Incompatible­­­­control

Damaged­­­­or­­­­missing­­­­rotor

Failed­­­­magnetic­­­­sensor

Not­­­­enough­­­­straight­­­­pipe­­­­between­­­­meter­­­­and­­­­
severe­­­­flow­­­­disturbance

Wrong­­­­K-Factor­­­­entered

Magnetic­­­­sensor­­­­failing­­­­to­­­­pick­­­­up­­­­each­­­­blade

Wrong­­­­time­­­­units­­­­on­­­­flow­­­­indicator

tROubLESHOOtING

Page 11

ARCHIVED

(Includes Dates Before 1/1/201

1)