Ar ch ive d, Includes dates before 5/05) – Seametrics EX100-200 Series v.1 User Manual
Page 6

Page 4
TABLE 2: PIPE WALL THICKNESS
PIPE SIZES
2"
2-1/2"
3"
4"
5"
6"
8" 10" 12" 16" 24" 30" 36"
0.109
0.120 0.120 0.120 0.134 0.134 0.148 0.165 0.180 — — — —
0.154
0.203 0.216 0.237 0.258 0.280 0.322 0.365 0.406 0.500 0.687 — 0.750
0.218
0.276 0.300 0.337 0.375 0.432 0.500 0.593 0.687 0.843 1.218 — —
0.083
0.095 0.109 0.134 0.160 0.192 0.271 — — — — — —
0.070
0.080 0.090 0.100 0.125 0.140 0.200 — — — — — —
0.157
0.188 0.219 0.250 0.250 0.250 0.313 — — — — — —
— — 0.280 0.290 —
0.310 0.330 0.350 0.370 0.400 — — —
IPS Steel
Schedule(10S)
IPS Schedule (40)
IPS Schedule (80)
Copper Tubing
(Type K)
Copper Tubing
(Type L)
Copper Pipe
Class 52 Duct. Iron
TABLE 1: DIMENSION "C"
NOMINAL PIPE SIZE
2”
2.5”
3”
4”
5”
6”
8”
10”
12”
16”
24”
30”
36”
10.20
10.12
10.03
9.86
9.69
9.52
9.18
8.84
8.50
7.82
—
—
—
15.20
15.12
15.03
14.86
14.69
14.52
14.18
13.84 13.50
12.82 11.46 10.44
10.42
17.24
17.14
17.04
16.84
16.74
16.54
16.14
15.84 15.54
14.84
—
—
—
-
-
-
20.89
20.69
20.49
20.19
19.89 19.49
18.79 17.49 16.49 15.39
MX101
MX201
MX115
MX215
INSTALLATION
AR
CH
IVE
D
(Includes Dates Before 5/05)