14
Calibrate to adjust sensor input . Zero is default .
F: -12,-11,-9,-8,-6,-5,-3,-2,0,2,3,5,6,8,9,11
C: -8,-7,-6,-5,-4,-3,-2,-1,0,1,2,3,4,5,6,7
L: -4,-3,-2,-1,0,1,2,3
U: -8,-7,-6,-5,-4,-3,-2,-1,0,1,2,3,4,5,6,7
Choose the next input with the + and - keys then the
NEXT key .
Press the PROGRAM key to go to next mode .
6.0 EVENT SENS MODE
Up to 32 sensor events can be programmed . A sensor
event can be assigned to either channel . Each sensor
event can be assigned to any day or combination of
days including the 3 holiday schedules (A, B and C) .
A sensor must be configured in step 5 for this mode to
function . This mode programs the start (ON) for the
sensor event . Set the end (OFF) time in Event Mode
section 4 .0 .
Press the PROGRAM key to bypass and go to next
mode .
Press the NEXT key to go to the first setting .
6.1 SET SENSOR EVENTS
Use the + and - keys to modify the flashing item .
Use the NEXT key advance to the next flashing item .
Choose the event number to program .
Choose the input . (Number and type (F, C, L or U) will
show . If the input is not configured as a sensor a
question mark (?) is shown .)
Choose the channel number .
Program hours and minutes to start the event .