8 Error codes

When detecting an operating state which is not permissible, the device will display an error

code. The following error codes are defined:
Err.1:

Exceeding of the measuring range

Indicates that the valid measuring range of the device has been exceeded.

Possible causes:

- Input signal to high

- Sensor shorted (0(4)-20mA)

Remedies:

- The error-message will be reset if the input signal is

within the limits.

- check transmitter and device configuration

(e.g. input signal).

Err.2:

Values below the measuring range

Indicates that the values are below the valid measuring range of the device.

Possible causes:

- Input signal is to low or negative

- Current below 4mA

- Sensor broken (4-20mA)

Remedies:

- The error-message will be reset if the input signal is

within the limits.

- check transmitter and device configuration

(e.g. input signal).

Err.3:

Display range has been exceeded

Indicates that the valid display range (9999 digit) of the device has been exceeded.

Possible causes:

- Incorrect scale

Remedies:

- The error-message will be reset if the display value

is below 9999.

Err.4:

Values below display range

Indicates that display value is below the valid display range of the device

(-1999 digit).

Possible causes:

- Incorrect scale

Remedies:

- The error-message will be reset if the display value

is above -1999.

Err.7:

System-error

The device features an integrated self-diagnostic-function which checks essential

parts of the device permanently. When detecting a failure, error-message Err.7

will be displayed.

Possible causes:

- Valid operating temperature range has been

exceeded or is below the valid temperature range

- Device defective

Remedies:

- Stay within valid temperature range

- Exchange the defective device.

Er.11: Value could not be calculated

Indicates a measuring value, needed for calculation of the display value, is faulty or

out of range.

Possible causes:

- Incorrect scale

Remedies:

- Check settings and input signal

1010 West Bagley Road, Berea, Ohio 44017 P 440.243.0888 F 440.243.3472 www.noshok.com