beautypg.com

KROHNE CORIMASS G-MFM 4085 EEx EN User Manual

Page 10

background image

10

Ensure that the screw thread of the round cover on the terminal box is well greased at all times.

NOTE: The grease used must be non corrosive to aluminium; typically it must be resin-
and acid free.


– Protect

the

sealing ring from damage.






11 12


- + DC
Coding of the
Outputs acc. to following PE
Table:

Term.
No.

Variant G

(1 current,1

puls

intrins.safe)

Variant H

(1 current, 1

status output.

intrins.safe)

Variant K

(1 current, 1

control inp.

intrins.safe)

Term.
No.

Variant L

(2 current,

intrins.safe)

Term.
No.

Variant M

1current, 1

Bus

intrins.safe)

I 1

current output

(+)

current output

(+)

current output

(+)

I 1

current

output 1

(+)

I 1

current output

1

(+)

I 1

current output

(-)

current output

(-)

current output

(-)

I 1

current

output 1

(-)

I 1

current output

1

(-)

B

puls output (+)

status output.

(+)

control input.

(+)

I 2

current

output 2

(+)

D

Bus

B

puls output (-)

status output. (-

)

control input. (-)

I 2

current

output 2

(-)

D

Bus




Please note,that the power supply terminals are behind a lid. To connect, shift lid upwards,