Technical data – KROHNE OPTIMASS 3000 EN User Manual
Page 29
TECHNICAL DATA
6
29
OPTIMASS 3000
www.krohne.com
03/2012 - 4001593001 - MA OPTIMASS 3000 R01 en
OPTIMASS 3300C non Ex I signal outputs with heating jacket / insulation
OPTIMASS 3300C non Ex I signal outputs with heating jacket / insulation
OPTIMASS 3300C non Ex I signal outputs with heating jacket / insulation
OPTIMASS 3300C non Ex I signal outputs with heating jacket / insulation
Ex d connection compartment
II 2 G Ex d [ib] IIC T6....T1
II 2 D Ex tD A21 IP6x T170°C
Ex e connection compartment
II 2 G Ex de [ib] IIC T6....T1
II 2 D Ex tD A21 IP6x T170°C
OPTIMASS 3300C Ex I signal outputs without heating jacket / insulation
OPTIMASS 3300C Ex I signal outputs without heating jacket / insulation
OPTIMASS 3300C Ex I signal outputs without heating jacket / insulation
OPTIMASS 3300C Ex I signal outputs without heating jacket / insulation
Ex d connection compartment
II 2(1) G Ex d [ia/ib] IIC T6....T1
II 2(1) D Ex tD [iaD] A21 IP6x T160°C
Ex e connection compartment
II 2(1) G Ex de [ia/ib] IIC T6....T1
II 2(1) D Ex tD [iaD] A21 IP6x T160°C
OPTIMASS 3300C Ex I signal outputs with heating jacket / insulation
OPTIMASS 3300C Ex I signal outputs with heating jacket / insulation
OPTIMASS 3300C Ex I signal outputs with heating jacket / insulation
OPTIMASS 3300C Ex I signal outputs with heating jacket / insulation
Ex d connection compartment
II 2(1) G Ex d [ia/ib] IIC T6....T1
II 2(1) D Ex tD [iaD] A21 IP6x T170°C
Ex e connection compartment
II 2(1) G Ex de [ia/ib] IIC T6....T1
II 2(1) D Ex tD [iaD] A21 IP6x T170°C
OPTIMASS 3000 / 3010C
OPTIMASS 3000 / 3010C
OPTIMASS 3000 / 3010C
OPTIMASS 3000 / 3010C without heating
/ insulation
II 2 G Ex ib IIC T6…T1
II 2 D Ex ibD 21 T150 °C
OPTIMASS 3000 / 3010C
OPTIMASS 3000 / 3010C
OPTIMASS 3000 / 3010C
OPTIMASS 3000 / 3010C with heating /
insulation
II 2 G Ex ib IIC T6…T1
II 2 D Ex ibD 21 T165 °C
MA_OPTIMASS_3000_en_120315_4001593001_R01.book Page 29 Tuesday, October 23, 2012 10:14 AM