beautypg.com

Technical data, 4 measuring ranges – KROHNE DK 46 I-DK 47 I EN User Manual

Page 28

background image

6

TECHNICAL DATA

28

DK46I - DK47I

www.krohne.com

08/2008 • 4000360001 MA DK46I-47I-R01-en

6.4 Measuring ranges

Measuring span 10 : 1
Flow values 100%

Reference condition:
water 68°F (20°C)
air 68°F (20°C), 17.4 psi (1.2 bar abs.) in a standard state

Other flow rate measuring ranges can be provided upon request.

The conversion of other materials or operating data (pressure, temperature, density, viscosity) is
done with the help of the calculation procedure as detailed in Directive VDI /VDE 3513

Sphere Ø

mm

Water

Air

DK46 I

DK47 I

DK46 I

DK47 I

[GPH]

[l/h]

[GPH]

[l/h]

[SCFH]

[l/h]

[SCFH]

[l/h]

4

0.65

2.5

-

-

0.22

5

-

-

4

-

-

-

-

0.3

8

-

-

4

-

-

-

-

0.6

16

0.6

16

4

-

-

-

-

1.5

40

1.5

40

4

-

-

-

-

2.5

60

3.8

100

6

1.3

5

1.3

5

3.8

100

-

-

6

3

12

3

12

9

250

9

250

6

6.5

25

6.5

25

18

500

18

500

6

11

40

11

40

30

800

30

800

6

16

60

16

60

45

1200

-

-

6

25

100

25

100

-

-

-

-

8

30

120

-

-

-

-

-

-

8

42

160

-

-

-

-

-

-

MA_DK46I_47I_R01_en_PRT.book Page 28 Tuesday, August 5, 2008 7:03 AM