TECHNICAL DATA

7

29

DK32 - DK34 - DK37

www.krohne.com

06/2014 - 4000287103 MA DK32-34-37-R05-en

Indicators of DK32 DK34 DK37/M8M with limit switches

Indicator DK37/M8E

DK32 - 34 /K./S

DK37M8M

Cable fitting

M16 x 1.5

Clamp terminal

1.5 mm

2

DK32 - 34 /K./S

Clamping range

4.5... 10 mm

DK37M8M

Clamping range

3...7 mm

DK32 - 34/K./L

∅ Connecting cable

approx. 7 mm

Cable length

approx. 1.7 m (other length on request)

Limit switch

SC2-N0

I7S2002-N

SJ2-SN

1

SJ2-S1N

1

Type NAMUR

2-wire

2-wire

2-wire

Switch element function

Normally

closed

Normally

closed

Normally open

Nominal voltage U

0

8 VDC

8 VDC

8 VDC

Pointer shaft not read

≥3 mA

≥3 mA

≤1 mA

Pointer shaft read

≤1 mA

≤1 mA

≥3 mA

DK32 DK34 with reed contact

Switching type

bistable

Switching reproducibility

<5% of full scale value

Breaking capacity

12VA

2

Max. supply voltage

30VDC

2

Max. current

0.5A

2

1 safety oriented
2 reduced values for Ex version

Cable fitting

M16 x 1.5

Cable diameter

8…10 mm

Clamp connection

M8M/K - 1.5mm

2

M8E - 2.5mm

2

Measurement signal

4...20 mA for 0…100% flow value, two-wire technology

Power supply

14.8...30 VDC

Min. power supply for HART

TM

20.5 VDC

Effect of supply power

<0.1%

External resistance dependency

<0.1%

Effect of temperature

<10 µA/K

Max. external resistance / load

impedance

640 Ohm (30 VDC)

Min. load for HART

®

250 Ohm

Software-firmware version

01.15

Identification number

3204090400

MA_DK32_34_37_R05_en_287103_PRT.book Page 29 Friday, June 6, 2014 11:42 AM