beautypg.com

Device description, 4 flammable products, 5 device category – KROHNE DK 32-DK 34 NEPSI Ex i User Manual

Page 5: 6 types of protection

background image

DEVICE DESCRIPTION

2

5

DK32 DK34

www.krohne.com

03/2013 - 4002598201 AD DK32/34 NEPSI Ex i R01 en

2.4 Flammable products

Atmospheric conditions:

Atmospheric conditions:

Atmospheric conditions:

Atmospheric conditions:

An explosive atmosphere is a mixture of air and flammable gases, vapours, mists or dusts under
atmospheric conditions. The following values define it
T

atm

= -20...+60°C / -4...+140°F and P

atm

= 0.8...1.1 bar.

Outside of this range, no key data are available as to ignition behaviour for most mixtures.

Installation conditions:

Installation conditions:

Installation conditions:

Installation conditions:

Variable area flowmeters operate outside of atmospheric conditions, which means that
explosion protection – regardless of the zone assignment – is fundamentally not applicable due
to the lack of key safety data for the interior of the measuring section.

2.5 Device category

Variable area flowmeters are designed according to GB 3836.1-2010 and GB 3836.4-2010

2.6 Types of protection

The variable-area flowmeter is designed in Intrinsic Safety type of protection, protection level
“ia“.

The marking is: Ex ia IIC T1-T6 Gb

Ex ia IIC T1-T6 Gb

Ex ia IIC T1-T6 Gb

Ex ia IIC T1-T6 Gb

WARNING!
Operation with flammable products is only permitted as long as no explosive fuel/air mixture
builds up on the inside of the flowmeter under operating conditions. The operator is responsible
for ensuring that the flowmeter is operated safely as regards the temperature and pressure of
the products used. In case of operation with flammable products the measuring units must be
included in the periodic pressure tests of the system. When using the device version H250/C...
(PTFE-liner, nonconductive) the min. conductivity of the medium must be 10

-8

S/m, in order to

avoid the electrostatic charge.

The marking contains the following information:

The marking contains the following information:

The marking contains the following information:

The marking contains the following information:

Ex ia

Ex ia

Ex ia

Ex ia

Intrinsic Safety type, protection level “ia“

IIC

IIC

IIC

IIC

suitable for gas group IIC, IIB and IIA

T1-T6

T1-T6

T1-T6

T1-T6

suitable for temperature class T6 ... T1

Gb

Gb

Gb

Gb

EPL, suitable for zone 1

AD_DK32_34_NEPSI_Ex_i_R01_en_4002598201_PRT.book Page 5 Friday, March 1, 2013 2:43 PM