2 ELECTRICAL CONNECTION

2.1 Equipotential bonding system

The IFM 4080 K-EEx and IFM 4080 K / i-EEx flowmeters must always be incorporated into
the equipotential bonding system of the hazardous area. This connection can be achieved
through the PE/FE conductor connected to the PE terminal in the terminal compartment
(see figure 1) or through a separate PE conductor, cross sectional area at least 4 mm

2

,

connected to the external PE clamp, placed below the converter housing.

2.2 Regular IFC 090-EEx electronics unit

The field cables that enter the terminal compartment of the IFC 090-EEx signal converter unit
(i.e. power supply, current and binary outputs) are non-intrinsically safe. To connect external
devices to the signal output terminals, the wiring requirements for the type of protection of
the compartment (standard: increased safety "e", optional: flameproof "d") must be conform
to the international or national standard involved (e.g. EN 60079-14).
The terminal arrangement is shown by figure 1 below.

Figure 1:

Terminal arrangement in terminal compartment.

Figure 2 Passive pulse/status output

Figure 3 Active current output

B1

B

B2

I+

I

L

N

(100…240Vac / 48…63 Hz)

L

½

L

½ (24Vac/dc)

BINARY

CURRENT

OUTPUTS

OUTPUT

PE (Protective Earth) terminal
FE (Functional Earth) terminal

PULSE, STATUS OUTPUTS
RESP. CONTROL INPUTS

Ri

500

I+

I

mA

+

_

½

B1 B

B2

I

150 mA

U

ext

32Vdc/24 Vac

000

Electronic or
electro-
mechanical
totalizer

I

150 mA

U

ext

e.g. signal
indicator