beautypg.com

KROHNE ALTOFLUX IFM 4080 K EEx EN User Manual

Page 10

background image

9

MODIS modul

Nominal values for voltage and current

P-SA
(passive current output )

Current:

4 .. 20 mA

Working voltage:

8 .. 30V

Voltage drop :

8V at 4mA

FA-ST
(frequency/pulse/status output
or control input)

Working voltage:

6 .. 30V

Working current:

< 110 mA

Voltage drop: in ON-state:

< 2V at 110 mA

Leakage current in OFF-state:

< 900

µ

A at 30V

Control input:
Input voltage LOW level:

< 3V

Input voltage HIGH level:

> 7V

Frequency range :

0 .. 12 KHz

DC-I
(active voltage source)

Voltage:

20V

Current

30 mA

Internal resistance:

260

Table 8: Nominal voltage and current values for the MODIS modules

IFC 090i-EEx version

Part No.

MODIS modules

Terminal designation

Ex-i1

2.11582.01.00

P-SA

FA-ST

I

I

B1

B1

Ex-i2

2.11582.03.00

P-SA

F-PA

I

I

D

D

Ex-i3

2.11582.02.00

P-SA

DC-I

I+

I

Ex-i4

2.11582.05.00

FA-ST

F-PA

B1

B1

D

D

Ex-i5

2.11582.06.00

FA-ST

DC-I

B1+

B1

Ex-i6

2.11582.07.00

FA-ST

FA-ST

B2

B2

B1

B1

Ex-i7

2.11582.08.00

P-SA

F-FF

I

I

D

D

Ex-i8

2.11582.09.00

FA-ST

F-FF

B1

B1

D

D

Table 9 : IFC 090i-EEx 24 Vac/dc versions.

IFC 090i-EEx version

Part No.

MODIS modules

Terminal designation

Ex-i1

2.12253.01.00

P-SA

FA-ST

I

I

B1

B1

Ex-i2

2.12253.02.00

P-SA

F-PA

I

I

D

D

Ex-i4

2.12253.03.00

FA-ST

F-PA

B1

B1

D

D

Ex-i6

2.12253.04.00

FA-ST

FA-ST

B2

B2

B1

B1

Ex-i7

2.12253.05.00

P-SA

F-FF

I

I

D

D

Ex-i8

2.12253.06.00

FA-ST

F-FF

B1

B1

D

D

Table 10: IFC 090i-EEx 100-230 Vac versions.

Due to mechanical and electrical limitations, only the in table 9 and 10 listed pairs of MODIS
modules are possible. The two modules each use two terminals of the bottom four terminals
of the flameproof terminal feed-through in the dividing wall between the electronics and
terminal compartment of the signal converter housing, except for the combination with
module DC-I (only applicable for 24 Vac/dc versions), where only two of the four terminals
are used. Interconnection of the two modules, P-SA and DC-I resp. FA-ST and DC-I is made
internally.