2 electrical connection – KROHNE VARIFLUX IFM 6080 K-EEx-i-EEx EN User Manual

Page 11

background image

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx

11

Electrical data of in-/output circuits

Terminals

Description

Nominal voltage

Maximum current

I+, I

Current output

15 V

22 mA

B1, B

, B2

Pulse, status, control in-/outputs

32 V

150 mA


The mains transformer is protected against overheating by a temperature breaker in series with the
primary winding. The temperature breaker is casted within the compound of the transformer and has an
opening temperature of 125 °C (± 5 K).

IFC 090i-EEx unit with MODIS modules

The IFC 090i-EEx electronics unit is equipped with a pair of MODIS-modules. It is equipped with one of
the following power supplies.

Electrical data of IFC 090i-EEx electronics unit

Power supply

Terminals Function

Electrical data

AC-version

L
N
PE

Live
Neutral
Protective Ground

U

n

= 100…230 Vac –15%/+10%

P

n

= 15 VA, U

m

= 253 V

AC/DC-version

1L Ÿ
0L Ÿ
FE

Live
Neutral
Functional Ground

U

n

= 24 Vac/dc

AC:

-15%/+10% or 20.4…26.4 Vac

DC:

-25%/+30% or 18…32 Vdc

P

n

= 10 W, U

m

= 253 V

NOTE:

The mains fuses for both electronics units are listed in Sect. 6 of this manual.


2 Electrical

connection

2.1 Equipotential

bonding

system

All EEx and EEx/i flowmeters must always be incorporated into the equipotential bonding system of the
hazardous area. This connection can be achieved through the PE/FE conductor connected to the PE
terminal in the terminal compartment (see figure of terminal arrangement below) or through a separate
PE conductor, cross sectional area at least 4 mm

2

, connected to the external PE clamp, placed below

the converter housing.

2.2 Connecting

cables

NOTE:

The below described cables are shown in the following connection diagram.

Cable A:

Signal cable for current output and binary outputs (pulse and status output): The cable parameters must
be in accordance with the regulations in the EN 60079-14 "Electrical installations in hazardous
locations" or an equivalent national standard. For the MODIS version with IFC 090i-EEx electronics unit
(right detail in connection diagram) the signal cable for the intrinsically safe signal in-/outputs must also
conform the requirements as specified in the relevant standard national code of practice for the
installation of electrical apparatus with type of protection Intrinsic Safety "i".

Cable B:

Power supply cable: The cable parameters must be in accordance with the regulations of the EN 60079-
14 "Electrical installations in hazardous locations" or an equivalent national standard.

The PE terminal must be connected to the protective ground conductor of the mains supply.

Rated voltage:

≥ 500 V

Examples: H07...-.,

H05...-.

Equipotential bonding conductor
Cross-sectional area:


4 mm

2

(equivalent to AWG 10)