Threaded thermometer with neck tube (TRA/TCA-S12/22/41)
Flange thermometer (TRA/TCA-F13/23/42)
TRA/TCA-S12/22
Thermowell length
Length of the measuring insert
[mm]
["]
[mm]
["]
160
6.30
315
12.40
250
9.84
405
15.94
400
15.75
555
21.85
TRA/TCA-S41
Thermowell length
Length of the measuring insert
[mm]
["]
[mm]
["]
160
6.30
315
12.40
220
8.66
375
14.76
280
11.02
435
17.13
INFORMATION!
The following applies when determining the length of the measuring insert for threaded
thermometers with neck tubes: distance from the underside of the seal (G thread) / two-thirds
of the thread height from the bottom (NPT thread) to the tip of the thermowell + 155 mm / 6.10".
TRA/TCA-F12/23
Insertion length
Length of the measuring insert
[mm]
["]
[mm]
["]
225
8.9
315
12.4
315
12.4
405
15.9
465
18.3
555
21.9
TRA/TCA-F42
Insertion length
Length of the measuring insert
[mm]
["]
[mm]
["]
225
8.86
315
12.40
285
11.22
375
14.76
345
13.58
435
17.13
INFORMATION!
The following applies when determining the length of the measuring insert for flange
thermometers: distance from the bottom of the flange to the tip of the thermowell + 90 mm /
3.54".
.book Page 49 Tuesday, August 17, 2010 12:18 PM