beautypg.com

Mode switch on the sensor to " min, Mode switch on the sensor to " max, Single channel architecture (1oo1d) – KROHNE OPTISWITCH 3x00C 2wire SIL EN User Manual

Page 10

background image

Overflow protection

(max. operation)

Dry run protection

(min. operation)

λ

du

18 FIT

43 FIT

DC

S

11 %

10 %

DC

D

90 %

81 %

MTBF = MTTF + MTTR

1.59 x 10

6

h

1.59 x 10

6

h

Mode switch on the sensor to "min."

Overflow protection

(max. operation)

Dry run protection

(min. operation)

λ

sd

39 FIT

45 FIT

λ

su

373 FIT

361 FIT

λ

dd

168 FIT

173 FIT

λ

du

36 FIT

37 FIT

DC

S

9 %

11 %

DC

D

82 %

82 %

MTBF = MTTF + MTTR

1.59 x 10

6

h

1.59 x 10

6

h

Diagnosis test period

<

100 sek.

Single channel architecture (1oo1D)

SIL

SIL

2

HFT

0

Sensor type

Type B

Mode switch on the sensor to "max."

Overflow protection

(max. operation)

Dry run protection

(min. operation)

SFF

97 %

93 %

PFD

avg

T

Proof

=

1 year

T

Proof

=

5 years

T

Proof

=

10 years

<

0.008 x 10

-2

<

0.039 x 10

-2

<

0.077 x 10

-2

<

0.019 x 10

-2

<

0.093 x 10

-2

<

0.186 x 10

-2

PFH

<

0.018 x 10

-6

/h

<

0.043 x 10

-6

/h

Mode switch on the sensor to "min."

10

OPTISWITCH series 3000 • - two-wire

Functional safety

32745

-EN