Surface quality
- Standard

R

a

approx. 3 µm (approx. 1.18

-4

in)

- Hygienic version 3A (OPTISWITCH

5250 C)

R

a

<0.8 µm (<3.15

-5

in)

Process fittings
- Thread

G¾ A, ¾ NPT, G1 A, 1 NPT

- Flanges

DIN from DN 25, ANSI from 1"

- hygienic fittings

Bolting DN 40 PN 40, Tri-Clamp 1", Tri-Clamp

1½" PN 10, conus DN 25 PN 40, Tuchenhagen

Varivent DN 50 PN 10

Gas-tight leadthrough (optional)
- leakage rate

<10

-6

mbar l/s

- pressure resistance

PN 64

- hygienic fittings

Bolting DN 40 PN 40, Tri-Clamp 1", Tri-Clamp

1½" PN 10, conus DN 25 PN 40, Tuchenhagen

Varivent DN 50 PN 10

Output variable
Output

Contactless electronic switch

Modes (adjustable)
- A

Max. detection or overflow/overfill protection

- B

Min. detection or dry run protection

Measuring accuracy
Hysteresis

approx. 2 mm (0.08 in) with vertical installation

Integration time

approx. 500 ms

Frequency

approx. 1200 Hz

Ambient conditions
Ambient temperature on the housing

-40 … +70 °C (-40 … +158 °F)

Storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions
Parameter

Limit level of liquids

Process pressure

-1 … 64 bar (-14.5 … 938 psi) depending on

the process fitting, e.g. flange