7.3 Exchange the electronics

To exchange the electronics in case of failure, it is not

necessary to dismount the instrument.
Dismounting the electronics module can destroy the housing

seal. Therefore only open the instrument if you want to insert a

new electronics module. The housing seal is supplied with the

electronics module.
You need an electronics module type SWE50T or SWE50C. If

you want to use an electronics module with a different signal

output (e.g. transistor output SWE50T), you can download the

suitable operating instructions manual from our homepage

under Downloads. Take note of the specifications in the

respective operating instructions manual.
To exchange the electronics module, proceed as follows:
1 Separate OPTISWITCH 4000 C from operating voltage
2 Loosen fixing screw (1) of the valve plug (2) with a wrench
3 Remove valve plug (2) acc. to drawing
4 Remove lateral fixing screw (7) with a crosstip screwdriver
5 Pull electronics module (4) carefully out of the housing (8)
6 Remove the plug of the connection cable (6) from the

socket on the oscillator (4)

7 Set the 16-step rotating switch (5) of the new replacement

electronics module (4) to the value of the defective

electronics module

8 Insert the connection cable (6) in the socket of the new

electronics module (4)

9 Insert electronics module (4) into the housing (8). Make

sure that the lateral thread on the electronics module is

above the hole on the housing (8)

10 Push the electronics module (4) flush into the housing (8)
11 Screw in the lateral fixing screw (7) with a crosstip

screwdriver

12 Plug the valve plug (2) to the instrument, make sure that

the profile seal (3) is placed correctly

13 Tighten fixing screw (1) with a wrench
OPTISWITCH 4000 C is again ready for operation.