Technical data – KROHNE OPTISWITCH 6500 C EN User Manual
Page 26

7
TECHNICAL DATA
26
OPTISWITCH 6500 C
www.krohne.com
01/2014 - 4000649104 - MA OPTISWITCH 6500 R04 en
Materials
Sensor housing
Stainless Steel 1.4301 / 304
Process connection
Stainless Steel 1.4404 / 316L
Sensor insulation
Virgin PEEK, FDA conform
Electrical connection
Cable gland M16: Plast or Nickel-plated brass
Plug M12: Nickel-plated brass
Process connections
Standard
Hygienic G½; DN38
Other
For other hygienic process connections, e. g. Tri-clamp, 11851, Varivent
please refer to the chapter "Order code".
Electrical connections
Power supply
12…36 VDC, 70 mA max.
Power consumption
1.7 W
Power-up time
< 2 s
Reaction time
Max. 0.1 s
Damping
0...10 s
Cable entry
M16 cable gland or M12 (4 pole Lumberg)
Output
Output (active)
Max. 50 mA, short-circuit and high-temperature protected
Output type
PNP or NPN
Output polarity
See drawing in chapter "Electrical connection".
Active "Low"
NPN and digital output; (-VDC + 2.5 V) ± 0.5 V; R
load
= 1 kOhm
Active "High"
PNP and digital output; (VDC - 2.5 V) ± 0.5 V; R
load
= 1 kOhm
Factory settings
Measure: ε
r
> 2; damping: 0.1 s
Approvals and certifications
CE
This device fulfils the statutory requirements of the EC directives.
The manufacturer certifies successful testing of the product by applying the
CE marking.
Other standards and approvals
Other standards and approvals
Other standards and approvals
Other standards and approvals
Electromagnetic compatibility (EMC)
EN 61326-1 (2006)
Vibration resistance
IEC 68-2-6, GL test 2 (standard and DN38 connection)
Hygiene
3A for G½ and DN38, FDA conform materials