beautypg.com

KROHNE BM 70A EEx EN User Manual

Page 9

background image

9

www.krohne.com

07/2010 - 4000662402 MA BM70x-Ex-AD-R02-en

3.2.1.2.

BM 70..-Ex with flange system WS

Standard-temperature version

WS

Allowable operating conditions

Material

Version

Rod

Cate-

gory

Zone

Gas

Group

Flange temperature /

product temperature

[°C]

Tank pressure

[bar]

0

-20 ... 60°C

(4)

-0,2 ... 0,1

(4)

(0,8 ... 1,1 bar abs.)

LPTFE

*

1A

1G

1

IIC

-40 ... 130

-1 ... 16

(2)

0

(3)

IIC

(3)

-20 ... 60°C

(4)

-0,2 ... 0,1

(4)

(0,8 ... 1,1 bar abs.)

PTFE

*

SS PTFE

*

1C
3A

1G

(3)

1

IIC

(1)

/ II B

-40 ... 130

-1 ... 16

(2)

0

(3)

IIC

(3)

-20 ... 60

(4)

-0,2 ... 0,1

(4)

(0,8 ... 1,1 bar abs.)

PP

*

SS PP

*

3B

1G

(3)

1

IIC

(1)

/ II B

-40 ... 100

(5)

-1 ... 16

PTFE

1B

2G

1

IIC

(1)

/ II B

-40 ... 130

-1 ... 16

(2)

SS PTFE

2A

2G

1

IIC

(1)

/ II B

-20 ... 130

-1 ...2

SS PP

2B

2G

1

IIC

(1)

/ II B

-20 ... 100

-1 ...2

*

with additional Metaglas pane (waveguide window)

High-temperature version with distance piece

WS

Allowable operating conditions

Material

Version

Rod

Cate-

gory

Zone

Gas

Group

Flange temperature /

product temperature

[°C]

Tank pressure

[bar]

0

-20 ... 60°C

(4)

-0,2 ... 0,1

(4)

(0,8 ... 1,1 bar abs.)

LPTFE

*

1A

1G

1

IIC

-40 ... 150

-1 ... 16

(2)

PTFE

*

SS PTFE

*

1C
3A

1G

(3)

0

(3)

IIC

(3)

-20 ... 60°C

(4)

-0,2 ... 0,1

(4)

(0,8 ... 1,1 bar abs.)

0

(3)

IIC

(3)

-20 ... 60

(4)

-0,2 ... 0,1

(4)

(0,8 ... 1,1 bar abs.)

PP

*

SS PP

*

3B

1G

(3)

1

IIC

(1)

/ II B

-40 ... 100

(5)

-1 ... 16

PTFE

1B

2G

1

IIC

(1)

/ II B

-40 ... 150

-1 ... 16

(2)

SS PTFE

2A

2G

1

IIC

(1)

/ II B

-20 ... 150

-1 ... 2

(2)

SS PP

2B

2G

1

IIC

(1)

/ II B

-20 ... 100

-1 ... 2

* with additional Metaglas pane (waveguide window)

(1) ...(5)

observe the application limitation for flange system WS


Application restrictions, flange system WS:

(1)

If the operator cannot rule out the risk of electrostatic charging of the antennas,
the antennas may only be used in conjunction with Gas Group II B.


(2)

To reduce the maximum allowable tank pressure, where flange and product
temperatures are > 100°C, see the following formula and table.


(3)

If the operator cannot rule out the risk of electrostatic charging of the antennas,
the antennas may only be used in Zone 1/Gas Group II B.


(4)

Limitation to atmospheric conditions in accordance with EN 60079-26


(5)

By using the standard microwave window of stainless steel (Type SS) the
allowed flange / product temperature is minimum -30 °C.