background image

07/2010 - 4000662402 MA BM70x-Ex-AD-R02-en

www.krohne.com

12

High-temperature version with distance piece V96

Temperature Class

Maximum flange temperature

[°C]

T6

85

(1)

T5

100

(1)

T4

135

T3

200

T2 , T1

250

(2)

Boundary conditions: Ambient temperature 55°C

(1)

observe application limitation for measuring devices BM 702-Ex /

BM 702 A-Ex

(2)

can be reduced, depending on engaged gasket materials used, refer to

”Standard Installation and Operating Instructions";
Where product temperature is > 200°C, a heat-resistant cable
with a continuous service temperature of 80°C is required



Application limitation for measuring devices BM 702-Ex / BM 702 A-Ex

Temperature Class

Maximum flange
temperature [°C]

Maximum Ambient

temperature [°C]

T6

75

40

T5

100

40

High-temperature version with distance piece WS

Temperature Class

Maximum flange temperature

[°C]

T6

85

(1)

T5

100

(1)

T4

135

T3 ... T1

150

Boundary conditions: Ambient temperature < 55°C

(1)

observe application limitation for measuring devices BM 702-Ex /

BM 702 A-Ex



Application limitation for measuring devices BM 702-Ex / BM 702 A-Ex

Temperature Class

Maximum flange
temperature [°C]

Maximum Ambient

temperature [°C]

T6

75

40

T5

100

40