beautypg.com

KROHNE BM 70A EEx EN User Manual

Page 13

background image

13

www.krohne.com

07/2010 - 4000662402 MA BM70x-Ex-AD-R02-en

3.3.3.

BM 70..-Ex with flange system WS Category 2 (Zone 1)


For BM 70..-Ex level gauges with flange system WS…-2G, use only the product temperature to
establish the temperature class.

Standard-temperature version

Temperature Class

Maximum flange temperature

[°C]

T6

85

(1)

T5

100

(1)

T4 ... T1

130 (100)

(2) (3)

Boundary conditions: Ambient temperature 55°C

(1)

observe application limitation for measuring devices BM 702-Ex /

BM 702 A-Ex

(2)

Figures in brackets in conjunction with rod 2B

(3)

Where product temperature is > 100°C heat-resistant cable with continuous

service temperature of 80°C is required



Application limitation for measuring devices BM 702-Ex / BM 702 A-Ex

Temperature Class

Maximum flange
temperature [°C]

Maximum Ambient

temperature [°C]

T6

50

40

T5

90

40


High-temperature version with distance piece WS

Temperature Class

Maximum flange temperature

[°C]

T6

85

(1)

T5

100

(1)

T4

135 (100)

(2)

T3 ... T1

150 (100)

(2)

Boundary conditions: Ambient temperature 55°C

(1)

observe application limitation for measuring devices BM 702-Ex /

BM 702 A-Ex

(2)

Figures in brackets in conjunction with rod 2B



Application limitation for measuring devices BM 702-Ex / BM 702 A-Ex

Temperature Class

Maximum flange
temperature [°C]

Maximum Ambient

temperature [°C]

T6

75

40

T5

100

40