4 Mounting

4.1 General instructions

Select an installation position you can easily reach for

mounting and connecting as well as later retrofitting of an

indicating and adjustment module. The housing can be rotated

by 330° without the use of any tools. You can also install the

indicating and adjustment module in four different positions

(each displaced by 90°).

Use the recommended cable (see chapter "Connecting to

power supply") and thighten the cable gland.
You can give your OPTISOUND 3010 C additional protection

against moisture penetration by leading the connection cable

downward in front of the cable entry. Rain and condensation

water can thus drain off. This applies mainly to mounting

outdoors, in areas where moisture is expected (e.g. by

cleaning processes) or on cooled or heated vessels.

Fig. 2: Measures against moisture penetration

The reference plane for the measuring range is the lower edge

of the transducer.
Make sure that the min. distance, corresponding to the so

called dead band, is maintained below the reference plane -

measurement is not possible in this areas. The exact value of

the dead band is stated in chapter "Technical data" in the

Supplement.

Installation position

Moisture

Measuring range

OPTISOUND 3010 C - 4 … 20 mA/HART

9