Signal Converter VFC 090

Full scale range

programmable in litres, m

3

, US/UK gallons, kg, tonnes, lbs, cub ft or standard

flow rate per second, minute or hour

Power Supply



Power Consumption

240/220/200/120/110/100 V AC + 10%
- 15%
230 V AC + 6%
- 10%
AC: 15 VA


} 48 to 63 Hz

Ambient temperature Tu

see diagram IV, page 59

Local display

3-field back-lit LCD

Display functions

actual flowrate and sum totalizer (8-digit), each programmable for continuous or
sequential display of measured parameters and error messages

Display units

Actual flowrate

Units list as per full scale range or % of full scale independently programmed

Totalizer liters,

m

3

, US/UK gallon, kg, tonnes, lbs, cub. ft.

Language of plain texts

German, English, French.

Display

1

st

field (top)

8 digit, 7-segment numeric display, symbols for key acknowledgement

2

nd

field (middle)

10-character, 14-segment text display

3

rd

field (bottom)

6 markers

t to identify actual display

Mass flow measurement

manual through keyboard or on-line with optional integrated temperature and
pressure sensors

Housing, signal converter

with separate connection compartment

Material die-cast

aluminium

Protection category
(EN 60529/IEC 529)

IP 65 & IP 67(better than NEMA 4 & 4X)

Current output

Operating data programmable, galvanically
isolated (not from frequency output)

Current

0/4 to 20 mA corresponding to flow values
independently programmable with min. span equal to 20% of full scale.

Accuracy

± 0.1% of FS

Temp. coefficient

100 ppm of fullscale range per 1

0

C.

Max. load at I

100%

(20 mA)

700

W

Error annunciation

I error = 2/22 mA programmable

Frequency output

operating data programmable, galvanically isolated (not from current output)

Pulse rate for q = 100%

10 to 36000000 pulse per hour
0.167 to 600000 pulses per minute
0.0028 to 10000 pulses per second (=Hz)
optionally in pulses per litre, m

3

, US/UK gallon, kg, tonne, lb, cub. ft.

Active output

short-circuit-proof suitable for electromechanical (EMC)
OR electronic (EC) totalizer

Amplitude max.

24V.

Load rating

see Table “pulse width” on page 61

Passive output

open collector for connection of active electronic totalizers
(EC) or switchgear

Input voltage (external supply)

5 to 24V

Load current

max. 100 mA

Ri 100

ohms.

Accuracy




Frequency output mode : +/- 0.3% of value.
Pulse output mode : 0% (no additional error)


60