2.3 FORMAT

Format for transmitting Measured values or Error messages is as follows :

If there are no Fatal Errors detected by 5090(I) :

:QV<QVval><QVunits>
:QN<QNval><QNunits>
:QM<QMval><QMunits>
:TV<TVval><TVunits>
:TN<TNval><TNunits>
:TM<TMval><TMunits>
:PR<PRval><PRunits>
:TR<TRval><TRunits>
:VE<VEval><VEunits>
:FR<FRval><FRunits>
:TP<TPval><TPunits>
:TE<TEval><TEunits>
:QF<QFval><QFunits>
:XT<XTval><XTunits>
:XP<XPval><XPunits>
:NP<NPval><NPunits>
:NE<NEval><NEunits>
:HE# nn Err#
:m<mesg m>

If there are Fatal Errors detected by 5090(I) then measurement is not made and transmitted :

:FEFATAL.ERROR
:HE# nn Err#
:
where,
QVval

Numeric value of measured volumetric flowrate.

QVunit

Unit of the volumetric flowrate value.

QNval

Numeric value of measured normalised flowrate.

QNunit

Unit of the normalised flowrate value.

QMval

Numeric value of measured mass flowrate.

QMunit

Unit of the mass flowrate value.

TVval

Numeric value of computed totalised volumetric flow.

TVunit

Unit of the totalised volumetric flow value

TNval

Numeric value of computed totalised normalised flow.

TNunit

Unit of the totalised normalised flow value

TMval

Numeric value of computed totalised mass flow.

TMunit

Unit of the totalised mass flow value

PRval

Numeric value of the operating pressure.

PRunit

Unit of the operating pressure

TRval

Numeric value of operating temperature.

TRunit

Unit of the operating Temperature.

VEval

Numeric value of flow velocity.

VEunit

Unit of the flow velocity.

FRval

Numeric value of measured vortex frequency

FRunit

Unit of measured vortex frequency

TPval

Numeric value of computed thermal power

TPunit

Unit of thermal power

TEval

Numeric value of computed thermal energy

TEunit

Unit of thermal energy

QFval

Numeric value of computed FAD

QFunit

Unit of FAD

XT val

Numeric value of measured external temperature

22