beautypg.com

Safety instructions, 5 pressure equipment directive (ped), 6 safety instructions from the manufacturer – KROHNE OPTIMASS 8000K EN User Manual

Page 7

background image

SAFETY INSTRUCTIONS

1

7

OPTIMASS 8000K

www.krohne.com

08/2010 - 4000921002 - MA OPTIMASS 8000k R02 en

1.5 Pressure Equipment Directive (PED)

To ensure the PED integrity of the meter, you MUST check that the serial numbers on the
converter nameplate and the sensor nameplate are the same.

To comply with the requirements of the Pressure Equipment Directive (PED) the manufacturer
provides all the relevant technical data in the technical data section of this handbook. Secondary
pressure containment is NOT supplied on this meter.

Tube failure

Where the meter is being used to measure high pressure gasses and / or gasses kept as liquids
by high pressure and / or where there is a risk of tube failure because of the use of corrosive or
erosive fluids, frequent pressure and / or thermal cycling, seismic or other shock loading, the
burst disc option MUST be purchased. For more information, please contact your nearest
representative.

1.6 Safety instructions from the manufacturer

1.6.1 Copyright and data protection

The contents of this document have been created with great care. Nevertheless, we provide no
guarantee that the contents are correct, complete or up-to-date.

The contents and works in this document are subject to copyright. Contributions from third
parties are identified as such. Reproduction, processing, dissemination and any type of use
beyond what is permitted under copyright requires written authorisation from the respective
author and/or the manufacturer.

The manufacturer tries always to observe the copyrights of others, and to draw on works created
in-house or works in the public domain.

The collection of personal data (such as names, street addresses or e-mail addresses) in the
manufacturer's documents is always on a voluntary basis whenever possible. Whenever
feasible, it is always possible to make use of the offerings and services without providing any
personal data.

LEGAL NOTICE!
The Pressure Equipment Directive places legal requirements on both the manufacturer and the
end user. Please read this section carefully!

Visual check

XXXXX

DANGER!
If it is suspected that the primary measuring tube has failed, de-pressurise the meter and
remove it from service as soon as it is safe to do so.