Technical data – KROHNE OPTIMASS 8000K EN User Manual
Page 30
6
TECHNICAL DATA
30
OPTIMASS 8000K
www.krohne.com
08/2010 - 4000921002 - MA OPTIMASS 8000k R02 en
Operating conditions
Maximum flow rates
Maximum flow rates
Maximum flow rates
Maximum flow rates
S15
3510 kg/h / 128.7 lbs/min
S25
11700 kg/h / 429 lbs/min
S40
41600 kg/h / 1525.3 lbs/min
S80
110500 kg/h / 4051.6 lbs/min
S100
325000 kg/h / 11916.6 lbs/min
Assumes operating density 1000 kg/m
3
/ 62.4 lb/ft
3
Ambient temperature
Ambient temperature
Ambient temperature
Ambient temperature
Compact version with Aluminium
converter
Standard temperature range: -40...+60°C / -40…+140°F
Cryogenic temperature range: -25...+40°C / -13…+104°F
Compact version with Stainless Steel
converter
Standard temperature range: -40...+55°C / -40…+131°F
Cryogenic temperature range: -25...+40°C / -13…+104°F
Remote versions
Standard temperature range: -40...+65°C / -40…+149°F
Cryogenic temperature range: -20...+65°C / -4…+149°F
Hazardous Area versions
Refer to temperature limits
Process temperature
Process temperature
Process temperature
Process temperature
Standard temperature range
Standard temperature range
Standard temperature range
Standard temperature range
Safe area (compact and remote version)
-70…+230°C / -94…+440°F
Hazardous area (standard temperature,
compact version only)
-40…+190°C / -40…+370°F
Hazardous area (standard temperature,
remote version only)
-40…+230°C / -40…+440°F
Hygienic connections
-70…+150°C / -94…+302°F
Cryogenic temperature range
Cryogenic temperature range
Cryogenic temperature range
Cryogenic temperature range
Safe area
-195…+40°C / -310…+104°F
Hazardous area
-195…+40°C / -310…+104°F
Nominal pressure at 20
Nominal pressure at 20
Nominal pressure at 20
Nominal pressure at 20°C / 68
C / 68
C / 68
C / 68°F
F
F
F
Measuring tube
Measuring tube
Measuring tube
Measuring tube
PED 97/23/EC
-1…100 barg / -14.5…1450 psig
FM
Pending
CRN / ASME B31.3
Pending
Fluid properties
Fluid properties
Fluid properties
Fluid properties
Permissible physical condition
Liquids, gases, slurries
Permissible gas content (volume)
Contact manufacturer for information.
Permissible solid content (volume)
Contact manufacturer for information.
Protection category (acc. to EN 60529)
IP 67, NEMA 4X
Installation conditions
Inlet runs
None required
Outlet runs
None required
MA_OPTIMASS_8000k_en_100817_4000921002_R02.book Page 30 Tuesday, August 17, 2010 2:08 PM