CONNECTION OF SEPARATE SYSTEMS

14

OPTISONIC 6300

www.krohne.com

03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en

3.5 Signal cable connections

See the pictures below for details.

Figure 3-1: Connecting the signal cable to the rail (small and medium version)

1 Connect the green cable to "DOWN"
2 Connect the blue cable to "UP"
3 Turn the screws clockwise to secure the cap

Figure 3-2: Connections in cable box (large version)

1 Connect the blue cable to the UP rail.
2 Connect the green cable to the DOWN rail.
3 Make connections in cable box.
4 Cable to converter