beautypg.com

The transit node receives health messages – Allied Telesis AlliedWare OS User Manual

Page 46

background image

Page 46 | AlliedWare™ OS How To Note: EPSR

Debugging

The transit node continues receiving Health messages for as long as the ring stays in a state of
Complete.

This is the packet shown in step

12 on page 41

of the master node debug output.

7. The transit node receives Health messages

Manager 9924-B>

EPSR Port1 Rx: 00e02b00 00040000 cd280619 8100e3e8 005caaaa 0300e02b

00bb0100 00541eed 00000000 0000cd28 0619990b 00400105 03e80000

00000000 cd280619 00010002 010000fb

EPSR Port1 Rx:

-----------------------------------------------------------------------

TYPE = HEALTH STATE = COMPLETE

CTRL VLAN = 1000 SYSTEM = 00-00-cd-28-06-19

HELLO TIME = 1 FAIL TIME = 2

HELLO SEQ = 251

-----------------------------------------------------------------------

Manager 9924-B>

EPSR Port1 Rx: 00e02b00 00040000 cd280619 8100e3e8 005caaaa 0300e02b

00bb0100 00541eec 00000000 0000cd28 0619990b 00400105 03e80000

00000000 cd280619 00010002 010000fc

EPSR Port1 Rx:

-----------------------------------------------------------------------

TYPE = HEALTH STATE = COMPLETE

CTRL VLAN = 1000 SYSTEM = 00-00-cd-28-06-19

HELLO TIME = 1 FAIL TIME = 2

HELLO SEQ = 252

-----------------------------------------------------------------------

.

.

.