Page 37 | AlliedWare™ OS How To Note: EPSR

Debugging

The master node continues sending Health messages, and increments the Hello Sequence
number with each message. If all nodes and links in the ring are intact, these Health messages
are the only debugging output you see.

The link between the master node’s primary port and the neighbouring transit node goes
down. Therefore, the master node detects that its primary port (port 1) has gone down.

2. The master node continues sending Health messages

.

.

.

Manager x900-48-A>
epsrHelloTimeout: EPSR test Hello Timer expired
EPSR Port1 Tx: 00e02b00 00040000 cd280619 8100e3e8 005caaaa 0300e02b

00bb0100 00541eef 00000000 0000cd28 0619990b 00400105 03e80000
00000000 cd280619 00010002 010000f9

EPSR Port1 Tx:
-----------------------------------------------------------------------
TYPE = HEALTH STATE = COMPLETE
CTRL VLAN = 1000 SYSTEM = 00-00-cd-28-06-19
HELLO TIME = 1 FAIL TIME = 2
HELLO SEQ = 249
-----------------------------------------------------------------------
EPSR Port2 Rx: 00e02b00 00040000 cd280619 8100e3e8 005caaaa 0300e02b

00bb0100 00541eef 00000000 0000cd28 0619990b 00400105 03e80000
00000000 cd280619 00010002 010000f9

EPSR Port2 Rx:
-----------------------------------------------------------------------
TYPE = HEALTH STATE = COMPLETE
CTRL VLAN = 1000 SYSTEM = 00-00-cd-28-06-19
HELLO TIME = 1 FAIL TIME = 2
HELLO SEQ = 249
-----------------------------------------------------------------------

3. The primary port goes down

EPSR test, Port 1 port down

Flush FDB EPSR: test vid: 2